KMU-1000

Color Ultrasound Scanner

Applications:

Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal


Technical Specification

1

Summary of main specifications and system of cart type color Doppler ultrasound

1.1

Trolley type all digital color Doppler ultrasonic mainframe

1.2

Ultrasonic host operating system: Windows operating system

1.4

Probes

Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume

probe

1.5

Applications and report

Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc.

☆1.6

carotid artery intima measurement thickness(IMT

☆1.7

Automatic spectral envelope measurement

1.8

Full digital transmission and reception of beam synthesizer

1.9

Color Doppler imagingC

1.10

Pulse Doppler ImagingPW

☆1.12

Coherent Contrast imagingCCI

1.12

Continuous wave Doppler imagingCW

☆1.13

B/C/D Real-time three synchronous imaging

☆1.14

Power Doppler imagingPDI

☆1.15

Direct power Doppler imagingDPDI

1.16

M mode imaging

☆1.17

Anatomic M mode imaging

☆1.18

Color Doppler M mode imaging

1.19

Elastography

☆1.20

Tissue Doppler imagingTDI

☆1.21

Strain rate imaging (SRI)

1.22

Tissue harmonic imagingTHI

1.23

Fusion harmonic imagingFHI

1.24

Speckle Reduce imagingSRI

☆1.25

Panoramic imaging

1.26

Deflection imaging

1.27

Trapezoidal imaging

1.28

Adaptive velocity optimization

☆1.29

Free hand 3D

1.30

Real time 3D imaging3D/4D

1.31

DICOM3.0

1.32

Monitor21.5 inchhigh definition ultrasonic display

1.33

≥13.3 inch touch screen

1.34

Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted.

1.35

The system has the function of on-the-spot upgrade

1.36

Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation.

1.37

Probe interface: 4

1.38

Chinese and English System, Chinese and English input, optional

1.39

Depth≥360mm

1.40

Extended imaging

2

Probes

2.1      Convex probe

Fundamental Frequency2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,

Harmonic Frequency

4.0MHz/4.6MHz/5.0MHz

2.2      

Linear probe

Fundamental Frequency4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz

Harmonic Frequency

8.0MHz/9.2MHz/10.0MHz,

2.3 Trans-vaginal probe

Fundamental Frequency

3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz

Harmonic Frequency

6.0MHz/7.0MHz/8.0MHz

2.4 Micro-convex probe

Fundamental Frequency

3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz

Harmonic Frequency

6.0MHz/7.0MHz/8.0MHz

2.5      Cardiac probe

Fundamental Frequency1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz

Harmonic Frequency

3.4MHz/3.8MHz/4.2MHz

2.6      

4D Volume probe

Fundamental Frequency

2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz

Harmonic Frequency

4.0MHz/5.0MHz/6.0MHz

3

2D imaging mode

3.1

Gain0100Step 2 adjustable

3.2

TGC8 segment adjustable

3.3

Maximum focus point≥7, which can be moved throughout the whole process.

3.4

Speckle reduction0-55 level

3.5

Space Synthesis0-22 levelLiner probe: 3 levelcardiac probe:0

3.6

Dynamic30-18035 levelstep 5 adjustable

3.7

Line densitylowmiddlehigh3 level

3.8

Frame correlation0-4,4 level

3.9

Noise reduction0-55 level

3.10

Edge Enhancement0-55 level

3.11

Sound power2-10, 9 level

3.12

Grey scale0-67, 67 level

3.13

False color0-6767 level

3.14

Image styleSoft-Comparison2 level


The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted

4

Color Doppler imaging mode

4.1

Blood gain0-100Step 2

4.2

Parameter displayVelocityVariance

4.3

B-RestrainB/W restrain):0-7, 7 level

4.4

Speed Through0-8, 8 level

4.5

Sampling number6-24, 7 level

4.6

Blood flow preferred0-8, 8 level

4.7

Filtering1-6, 6 level

4.8

Sound power2-6, 4 level

4.9

Noise reduction0-4, 4 level

4.10

Smooth treatment0-44 level

4.11

Frame correlation0-66 level

4.12

ChromatographyBlood flow graph):0-3737 level

4.13

Line densityLow-Middle-High3 level

4.14

Frequency4 level adjustable

4.15

VelocityMinimum 0.4KMaximum 40.5K

Convex probe0.4K-4.3K-38.5K

Linear probe0.4K-14.7K-39.0K

Trans-vaginal probe0.4K-7.8K-39.7K

Volume probe0.4K-4.2K-34.8K

Micro-convex probe0.4K-10.3K-40.5K

cardiac probe0.4K-7.8K-39.7K


PSThe frequency of the probe changes and the frequency value changes


PSFrame rate changes with speed

5

Pulse wave DopplerPW

1

Gain0-100Step 2

5.2

Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close

5.3

Sample volume0.5mm~30mm

5.4

Blood angel-75—75 degreeStep 5

5.5

False color0-6767 level

5.6

Dynamic range20-404 level

5.7

Filter0-9, 9 level

5.8

Smooth treatment1-44 level

5.9

Sound power2-54 level

5.10

Volume0-100, 10 levelStep 10

5.11

Audio filtering0-44 level

5.12

Base line-1.0~1.0,

5.13

Grey map0-6767 level

5.14

Scan velocity100-500, 6 level

5.15

PRF:Minimum 0.5KMaximum 87.5K

Convex probe0.5K-4.3K-63.3K

Linear probe0.5K-14.5K-78.4K

Trans-vaginal probe0.5K-8.1K-78.4K

Volume probe0.5K-4.2K-53.8K

Micro-convex probe0.5K-10.3K-81.1K

cardiac probe0.5K-4.3K-87.5K

5.16

Frequency4 level


PSThe frequency of the probe changes and the PRF value changes


PSThe frequency of the probe changes and the frequency value changes

6

Continuous Wave DopplerCW

6.1

Support probeCardiac probe

6.2

Adjustment of B mode parameters is switchable

6.3

Gain0-100Step 2

6.4

Sampling line position is adjustable

6.5

PRF:0.9K~36.1K

6.6

Baseline-1.0~1.0

6.7

Blood angel-75~75 degree

6.8

Grey map0-67

6.9

Scan velocity100-300

6.10

False color0-67

6.11

Dynamic range20-40

6.12

Filtering0-99 level

6.13

Smooth treatment1-4

6.14

Frequency2.0MHz/2.3MHz/2.5MHz/3.0MHz4 level adjustable

6.15

Sound power2-5

6.16

Volume0-100

6.17

Audio Filtering0-4

☆7

Anatomical M imaging

7.1

Support probeConvex probe, Linear probe,Cardiac probe

7.2

Adjustment of B mode parameters is switchable

7.3

Gain0-100Step 2

7.4

M Sampling line angel is adjustable

7.5

M Sampling line length is adjustable

7.6

Sampling line3Can be displayed or hidden separately

☆8

Blood flow M modeMC

8.1

Adjustment of B mode parameters is switchable

8.2

Gain0-100Step2

8.3

MC Sampling line angel is adjustable

8.4

MC Sampling line length is adjustable

8.5

Frequency4 level

8.6

Sampling number6-24

8.7

Speed through0-8, 8 level

8.8

Scan velocity150-500

8.9

Frame correlation0-6, 6 level

8.10

Filtering1-66 level

8.11

Blood flow preferred0-88 level

8.12

Smooth treatment0-4,4 level

8.13

Map0-37, 37 level

☆9

Elastography

9.1

Adjustment of B mode parameters is switchable

9.2

Gain0-100Step 2

9.3

B/EDouble real-time display on the same screen

9.4

Probe displacement curve display:Up/Down

9.5

Pressure indicator bar display

9.6

Frequency8-9 levelAdjustableAccording to the probe display

9.7

Noise reduction0-2, 2 level

9.8

Frame correlation0-3, 3 level

9.9

Comparison0-13, 13 level

9.10

False color0-33 level

9.11

Don’t support cardiac probe

☆10

Tissue Doppler imagingTDI

10.1

Support probe: Cardiac probe

10.2

Adjustment of B mode parameters is switchable

10.3

Gain0-100step 2

10.4

ROI area adjustable

10.5

Sampling number6-24

10.6

Velocity0.4K-8.0K

10.7

Frame correlation0-66

10.8

Tissue preferred0-7, 7 level

10.9

Frequency2.0MHz/2.3MHz/2.5MHz/3.0MHz

10.10

Support color reversal

☆11

Strain rate imaging

11.1

Support probe: Cardiac probe

11.2

Adjustment of B mode parameters is switchable

11.3

ROI area adjustable

11.4

Gain0-100Step 2

11.5

Sampling number6-246 level

11.6

Axial average1-44 level

11.7

Velocity0.4K-8K

11.8

Frame correlation0-66 level

11.9

Tissue optimization0-77 level

☆12

Panoramic imaging

12.1

Support probeLinear probe

12.2

Speckle Reduction0-5, 5 level

☆13

Deflection imaging

13.1

Support probeLinear probe

13.2

Adjustment of B mode parameters is switchable

13.3

Deflection angel8 level

13.4

Speckle reduction0-5, 5 level

13.5

Dynamic rate30-180Step 5

13.6

Line densitylow-middle-high3 level

13.7

Frame Correlation0-44 level

13.8

False color0-67, 67 level

13.9

Image styleSoft-Comparison2 level

13.10

Noise reduction0-5, 5 level

13.11

Edge Enhancement0-55 level

13.12

Sound power2-108 level

13.13

Grey map0-6767 level

☆14

Trapezoidal imaging

14.1

Probe supportlinear probe

14.2

Adjustment of B mode parameters is switchable

14.3

Deflection angel:8 level

14.4

Speckle reduction:0-5, 5 level

14.5

Dynamic rate:30-180,Step 5

14.6

Line density:low-middle-high,3 level

14.7

Frame Correlation:0-4, 4 level

14.8

False color:0-67, 67 level

14.9

Image style:Soft-Comparison,2 level

14.10

Noise reduction:0-5, 5 level

14.11

Edge Enhancement:0-5,5 level

14.12

Sound power:2-10,8 level

14.13

Grey map:0-67, 67 level

14.14

Space Synthesis0-2, 2 level

☆15

Freehand 3D imaging

15.1

Support probeconvex probe, linear probe

15.2

Display model: 4 pictures

15.3

Image Rotation X/Y/Z Axis

15.4

Multi-slice Visibility

16

Real-time 4D imaging

16.1

Support probe: 4D volume probe

16.2

Adjustment of B mode parameters is switchable

16.3

Gain0-100Step 2

16.4

Display modelone imagetwo imagesfour images

16.5

Image RotationX/Y/Z Axis

16.6

Multi-slice Visibility

16.7

Light&Shade inversion

16.8

Smooth0-4, 4 level

16.9

Threshold level0-129, Step 3

16.10

Transparency1-509Step 10

16.11

Render type4 kindsSurfacemaximumminimumperspective

17

Extended Imaging

17.1

Gain0100Step 2

17.2

TGC8 segment adjustable

17.3

Maximum focus point≥7, which can be moved throughout the whole process.

17.4

Speckle reduction0-55 level

17.5

Space Compound0-22 levelLinear probe: 3 leveldon’t support cardiac probe

17.6

Dynamic range30-18035 levelStep 5

17.7

Line densityLowMiddleHigh3 level

17.8

Frame correlation0-4,4 level

17.9

Noise reduction0-55 level

17.10

Edge enhancement0-55 level

17.11

Sound power2-10, 9 level

17.12

Grey map0-67, 67 level

17.13

False color0-6767 level

17.14

Image styleSoft-Comparison2 level

17.15

Extended level: Maximum 72 level

Convex probe9 level

Trans-vaginal probe72 level

Micro-convex probe29 level

Cardiac probe40 level

4D Volume probe17 level


PSThe screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted


PS: When the probe scan range reaches the maximum, the space synthesized is 0.

18

Measurement and analysis function:

18.1

General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle

18.2

CardiacAutomatic spectrum envelopeLVMain Pulmonary artery diameterRVEDdRVEDsLVMLAVHRMVFAOARLVOTTVFPulmonic valvePulmonary veinRVDoppler fetal heart soundLVETLVMLVMIAV

18.3

Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall)

18.4

OBFetal routineAFITWGSCRlOFDHLulnaNTFibulaNbonelRadialTibia

18.5

GYNuteruscervixcorpus uteri/cervix uterusleft ovarian veinright ovarian veindominant follicleintima thickness

18.6

Urology: prostateresidual urineleft kidneyright kidneyleft suprarenal veinright suprarenalleft testisright testisleft seminal vesicleright seminal vesicle

18.7

AbdomenliverCHDpartal vein diametercholecystCBDpancreasspleenInternal diameter of abdominal aortakidney

18.8

Small partsThyroid

18.9

Software packageMeasurement packageSoftware packageMedical records management software package

19

Graphic and text management system

19.1

Host build in 2 hard diskSSD 120+1T),Start fast and stable

19.2

Movie playback≥1200 frames

19.3

Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.

19.4

Type of report is 16

19.5

One key fast report graphic and text management

20

Interface

20.1

USB interface4

20.2

HDMI interface1

20.3

RJ-45 interface1

20.4

Grounding wire interface1

20.5

DVD RW1

 21

Configuration

21.1

Trolley type full digital color Doppler ultrasound diagnostic system

21.2

Probe: convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional)

21.3

≥13 quick adjusting knobs

22:

Technology, after-sales service and other requirements

22.1

After acceptance, the warranty is free for two yearsProvide manufacturer warranty certificate

22.2

Manufacturer has ISO13485 certification and EU CE certification.